Skip to main content
Documentation
Preview
You're viewing the Next docs — a rolling preview of in-development changes. The current release docs may differ.

System Updates

Nexigon Agent installs system updates with Rugix Ctrl or RAUC. The update engine writes a bundle, the file that contains an update, to the inactive copy of the system and makes the device boot that copy. The agent decides which bundle to install and when, and reports the result. Set Up System Updates shows how to prepare an image and its releases.

The agent implements the OTA update contract of Nexigon Hub. Operators set the desired release and update policies in the dev.nexigon.ota.config device property. The agent applies this property over the defaults from its own configuration, so an image can ship with a default release and be switched to another one later. It publishes its progress in the dev.nexigon.ota.status property and records each installation and its outcome as an event in the ota category.

The Check Cycle

The agent checks for updates after it connects to Nexigon Hub, every check-interval-secs, when a deferred update becomes due, and when the nexigon.ota.check command runs. Each check:

  1. Commits a newly booted system, if one awaits its commit. Committing confirms to the update engine that the new system works.
  2. Determines the name and version of the running system.
  3. Resolves the configured release to a package version and stops if the device already runs it. If the release requires that the device first runs a checkpoint release, the agent installs the checkpoint first.
  4. Waits while a hold, a maintenance window, a retry delay, or a spread defers the update.
  5. Has the update engine download and install the bundle for the running system, and reboots the device.

Scheduled checks wait for an additional random delay of up to check-jitter-secs, so that devices whose checks fall due at the same time, for example when a maintenance window opens, do not reach Nexigon Hub at once. Without a configured release, the device does not update.

After the reboot, the next check reports whether the device runs the installed version or has rolled back to the previous one. Because the agent reads the running version from the image on every check, the report is correct even after a rollback or a manual installation.

The Running System

The agent identifies the running system by its system name and version string. It reads them from /etc/rugix/system-build-info.json, which Rugix Bakery writes into every image, and otherwise from IMAGE_ID and IMAGE_VERSION in /etc/os-release.

The system name selects the bundle of a release: <name>.rugixb for Rugix Ctrl or <name>.raucb for RAUC, unless asset sets another filename. The device runs a package version when its version string equals the imageVersion metadata of that version. To find the package version that it runs, the agent resolves the version string as a tag of the package.

Installation and Commit

StepRugix CtrlRAUC
Installrugix-ctrl update install with the bundle’s download URLrauc install with the bundle’s download URL, by streaming
Rebootrugix-ctrl system reboot --spare, which boots the new system once on trialsystemctl reboot
Commitrugix-ctrl system commit once the agent has connected to Nexigon HubThe rauc-mark-good service, independently of the agent

With Rugix Ctrl, a new system that cannot connect to Nexigon Hub is never committed, so a reboot returns the device to the previous system. With RAUC, the default rauc-mark-good service commits any system that boots. Rollback describes how to roll back systems that boot but do not work.

With use-bundle-hash, the agent passes the rugix.bundleHash metadata of the bundle to Rugix Ctrl, which then verifies the bundle against this hash instead of a signature. This option is not available for RAUC.

The status describes the update engine in updater: its version, its slots, the booted slot, and the slot that the device boots next. See Update System.

Failures

Failures of the integration do not stop the agent. With invalid settings, for example with both integrations enabled, the agent logs an error and runs without system updates. When a check fails, the agent logs the error and retries after a delay, or within check-jitter-secs after it reconnects to Nexigon Hub. A failed installation counts toward the retry policy of the configuration. Calls of rugix-ctrl, rauc, and systemctl that do not finish within 10 minutes fail, except installations, which include the download.

Stopping the agent, for example when the device shuts down, interrupts an installation in progress, and the agent does not reboot. Its next check keeps the running system active and reports a failed attempt with the failure code interrupted. RAUC finishes an installation in the background even after the agent stops rauc install, so the check first waits until RAUC is idle. A lost connection or a hold lets an installation finish.

Settings

System Updates lists the settings of the integration. Enable at most one of [integrations.rugix.system-updates] and [integrations.rauc.system-updates].